    script:
      - id: fan_control_power
        then:
          - lambda: |-
              // Normal On:
              // switch fan on when either temperature or humidity is above "max", unless humidity/temperature is below "min"
              if (
                !id(fan_speed).state &&
                (
                  (id(bme280_temperature).state >= atoi(id(temperature_max).state.c_str()) && id(bme280_humidity).state    >= atoi(id(humidity_min).state.c_str())) ||
                  (id(bme280_humidity).state    >= atoi(id(humidity_max).state.c_str())    && id(bme280_temperature).state >= atoi(id(temperature_min).state.c_str()))
                )
              ) {
                ESP_LOGI("fan", "Fan On");
                auto call = id(fan_speed).turn_on();
                call.perform();
              }
    
              // Forced Off, ignoring Hysteresis:
              // switch fan off when either temperature or humidity are below "min", unless humidity/temperature is above "max"
              else if (
                id(fan_speed).state &&
                (
                  (id(bme280_temperature).state <= atoi(id(temperature_min).state.c_str()) && id(bme280_humidity).state    <= atoi(id(humidity_max).state.c_str())) ||
                  (id(bme280_humidity).state    <= atoi(id(humidity_min).state.c_str())    && id(bme280_temperature).state <= atoi(id(temperature_max).state.c_str()))
                )
              ) {
                ESP_LOGI("fan", "Fan Off (forced)");
                auto call = id(fan_speed).turn_off();
                call.perform();
              }
    
              // Normal Off, respecting Hysteresis:
              // switch fan off when both temperature and humidity are below "max minus hysteresis"
              else if (
                id(fan_speed).state &&
                (
                  id(bme280_temperature).state <= atoi(id(temperature_max).state.c_str()) - atoi(id(temperature_hysteresis).state.c_str()) && 
                  id(bme280_humidity).state    <= atoi(id(humidity_max).state.c_str())    - atoi(id(humidity_hysteresis).state.c_str())
                )
              ) {
                ESP_LOGI("fan", "Fan Off");
                auto call = id(fan_speed).turn_off();
                call.perform();
              }